Terrace Door Interface Water Ingress
Water ingress at a rear terrace door was linked to defects across the door assembly, sill, perimeter sealing and rendered reveal, requiring a coordinated building-envelope remediation scope.

Client Problem
Water ingress was affecting the rear of the property around a terrace door interface, with consequential damage to internal finishes at first-floor and ground-floor level.
Initial Symptoms
Moisture-related damage to the internal door reveal and staining to ceilings in the first-floor rear bedroom and ground-floor living area, alongside a previous borescope investigation opening.
Investigation
Targeted inspection of the terrace door and surrounding reveal focused on the interfaces between the door assembly, sill, perimeter seals and external monocouche render.
Findings
The existing terrace door assembly required replacement, the sill required mechanical restraint, perimeter weather sealing required renewal and areas of the external monocouche reveal were defective or missing, with rain-shedding detailing requiring improvement.
Root Cause
A combined failure at the external door and reveal interface, where deficiencies in sill restraint, perimeter sealing and local render weathering continuity created a route for water penetration.
Recommended Solution
Replace the terrace door assembly, inspect and prepare the structural opening, install the new door and infill panel, mechanically secure the sill, renew perimeter sealing and reinstate defective monocouche render with appropriate drip and rain-shedding detailing.
Remediation
The remedial scope addresses the external envelope first, followed by making good the internal reveal, reinstatement of the opened ceiling section and stain-blocking and redecoration of affected ceiling finishes.
Outcome
A single cause-focused remediation package was established across the door, sill, sealant and render interfaces, with consequential internal repairs separated from the external works required to address the ingress mechanism.