Skip to content
← Case Studies
Claims Consultant · New-Build Residential

New-Build Roof Installation Failure

Recurrent water ingress at a new-build home traced through manual investigation and flood testing to widespread defects in the original pitched-roof installation, leading to complete roof-covering renewal, replacement of two Velux flashing kits and internal reinstatement.

New-Build Roof Installation Failure
01

Client Problem

Recurrent internal water ingress at a relatively new residential property had not been satisfactorily explained by the visible symptoms. A localised investigation route was initially being considered, while the possibility of a wider construction defect remained.

02

Initial Symptoms

Internal water staining and moisture damage following rainfall, with the pattern of ingress indicating that the visible internal damage was unlikely to identify the true point of entry.

03

Investigation

Initial internal and external assessment was followed by systematic manual investigation of the pitched roof, including flood testing to trace the ingress paths. This allowed the complete roof covering, tile courses and key interfaces to be reviewed before unnecessary further opening-up was undertaken.

04

Findings

The manual investigation and flood testing identified widespread poor installation across the roof covering rather than a single isolated failure. The extent of the defects meant that continued localised investigation or patch repair would not provide an appropriate long-term solution.

05

Root Cause

Original construction workmanship and setting-out defects across the pitched roof covering, compounded by the sensitivity of an approximately 18° low-pitch installation to weathering and interface detailing, and improperly installed flashing kits around the Velux windows.

06

Recommended Solution

Renew the roof covering as a complete system rather than continue with localised patch repairs, including correct tile setting-out and headlap, replacement of the two Velux flashing kits and remediation of consequential internal damage.

07

Remediation

The managed repair was delivered in full. The existing roof covering was stripped and replaced across the entire roof, both Velux flashing kits were replaced and integrated into the renewed covering, and the associated internal damage was reinstated. Progress was communicated to the claims consultant and policy holder throughout the works.

08

Outcome

The project progressed from recurrent water-ingress investigation to complete remediation of the underlying latent construction defect. The full roof covering and both Velux flashing kits were successfully replaced, with associated internal reinstatement completed, providing a coordinated investigation-to-remediation outcome rather than repeated localised repairs.

Start a Project

Discuss investigation, diagnosis or remediation with our team.

Contact Our Team→

Accredited & registered

CABEBDMARICS
Our credentials →

    We use analytics cookies to understand how the site is used and to improve it. Nothing is measured until you choose, and declining turns measurement off entirely.